Modular Data Centers
MC6000 Micro-Module Data Center
The MC6000 is a factory-standardized micro-module data center that integrates IT cabinets, power distribution, precision cooling, cabling, security and intelligent monitoring into a single deployable system. Configurable as single-row or dual-row sealed cold/hot aisle modules from 3 to 48 cabinets, MC6000 supports IT loads up to 310kW per module and reaches Tier IV reliability, with a typical build-to-commission cycle of just 3-6 weeks.





Engineered for Reliable, Efficient Data Center Deployment
MC6000 combines standardized modular construction with intelligent monitoring and high-density power and cooling, giving operators a data center infrastructure platform that is fast to deploy, simple to maintain and efficient to run.
Standardized Modular Architecture
Highly generic components and standardized module design avoid system design errors and simplify sourcing and maintenance.
Fault-Tolerant, Low-Interference Design
System-level fault tolerance combined with strong/weak current separation reduces electromagnetic interference and improves reliability.
3-6 Week Delivery
Standardized modular design supports mixing sizes and power ratings, enabling product handover in as little as 3-6 weeks.
Intelligent Micro-Module Monitoring
A unified monitoring platform manages in-module power, environment, security and fire systems, with precision metering for accurate energy analysis.
High-Density Integrated Power & Cooling
Industry-leading power density and efficiency with sealed cold/hot aisle containment, available in single-row or dual-row configurations to isolate airflow and eliminate hot spots.
Low PUE, Scalable Expansion
Sealed aisle containment keeps PUE lower than traditional server rooms, while modules can be expanded incrementally as capacity needs grow.
OEM & ODM Capabilities
Every MC6000 module is configured to project requirements — from aisle layout and cabinet count to power topology and cooling type — and delivered under the customer’s own brand.
Custom Aisle & Cabinet Configuration
Single-row or dual-row sealed aisle layouts, 3-24 cabinets per single row or 6-48 per dual row, sized to available floor space.
Custom Power Topology
Integrated UPS, external precision distribution cabinet, or smart busway configurations, in AC or DC power systems.
Custom Cooling Type
Air-cooled or chilled-water in-row cooling, sized from 12kW to 70kW per unit to match module heat load.
Battery & Backup Options
Lead-acid or lithium-ion battery support, deployed as battery cabinet, rack or box, with 15-240 minute backup configured to project needs.
Monitoring & Software Integration
Unified monitoring platform can be configured to integrate with the customer's existing building or network management systems.
Branded Enclosure & Nameplate
Exterior panels, door fascia and display branding customized to the customer's own product identity for OEM/ODM programs.
Technical Specifications
MC6000 configuration and parameters covering module dimensions, power system, cooling and reliability rating.
| Micro-Module Type | Air-cooled or chilled-water in-row cooling, single-row or dual-row sealed cold/hot aisle containment |
|---|---|
| Channel Door | Motorized bi-directional sliding full-glass door |
| Dual-Row Sealed Aisle (L x W x H) | L x 3600 x 2550/2750mm; L x 3400 x 2550/2750mm; L x 3200 x 2550/2750mm (L ≤ 15m) |
| Single-Row Sealed Aisle (L x W x H) | L x 2465 x 2550/2750mm; L x 2365 x 2550/2750mm; L x 2265 x 2550/2750mm (L ≤ 15m) |
| Cabinets per Module | Single-row: 3-24; Dual-row: 6-48 |
| Power System | AC 380/400/415Vac, 50/60Hz, 3Ph+N+PE; DC -48/240/336Vdc, positive & negative +PE |
| Operating Environment | Ultra-low temperature: -40~45°C; T1 condition: -25~45°C; T3 condition: -5~45°C |
| Reliability Tier & Altitude | Tier II-III, expandable to Tier IV; derate above 1000m altitude |
| Parameter | Value | Notes |
|---|---|---|
| IT Load per Module | ≤200kW / ≤310kW | Integrated UPS or busway / precision distribution cabinet |
| Integrated UPS Rating | 25-200kVA | Efficiency ≥96% |
| Battery Backup Time | 15-240 min | Configured to project needs |
| Reliability Tier | Tier II-IV | Expandable design |
| Subsystem | Dimensions | Input Power | Capacity | Rating | Refrigerant / Protection | Remarks |
|---|---|---|---|---|---|---|
| IT Cabinet | 600/800 x 1200 x 2000/2200mm; 600/800 x 1100 x 2000/2200mm; 600/800 x 1000 x 2000/2200mm | — | 42U / 47U usable space | IP20 | — | Standard rack cabinet |
| Integrated UPS (built-in) | — | 380/400/415Vac, 50/60Hz, 3Ph+N+PE | 25-200kVA | Efficiency ≥96%, PF full load >0.99 / half load >0.98 | Surge protection Class B, C | — |
| Precision Distribution Cabinet (external UPS) | — | 380/400/415Vac, 50/60Hz, 3Ph+N+PE | Input breaker 160A/250A/400A/630A | — | Surge protection Class B, C | — |
| Smart Busway | — | 380/400/415Vac, 50/60Hz, 3Ph+N+PE | Input breaker 160A/250A/400A/630A | IT output 40A/1P, 40A/3P, 63A/3P | — | — |
| Air-Cooled In-Row AC | Indoor unit 300/600 x 1000/1100/1200 x 2000/2200mm | AC 380/400/415Vac, 50/60Hz (optional DC 240/336Vdc) | 12-60kW | — | Refrigerant R410A, optional pump | — |
| Chilled-Water In-Row AC | Indoor unit 300/600 x 1000/1100/1200 x 2000/2200mm | AC 380/400/415Vac, 50/60Hz, 3Ph+N+PE | 20-70kW | — | Coolant: water / ethylene glycol solution | — |
Construction & Configuration
MC6000 integrates six core subsystems in a factory-standardized enclosure, built for fast on-site assembly and simplified maintenance.
Micro-Module Enclosure & Sealed Aisle
Single-row or dual-row cold/hot aisle containment with motorized sliding glass channel doors.
IT Cabinets
42U or 47U usable rack space, 3-24 cabinets per single row or 6-48 per dual row, IP20 protection.
Integrated Power System
Integrated UPS, external precision distribution cabinet or smart busway, rated 25-200kVA.
In-Row Cooling System
Air-cooled (12-60kW) or chilled-water (20-70kW) in-row units matched to module heat load.
Fire Suppression & Early Warning (Optional)
Extra-early smoke detection and fire pre-warning available as an optional add-on module.
Intelligent Monitoring & Management Platform
Unified monitoring of power, environment, security and fire systems, with precision energy analysis.
Standards & Test Documentation
MC6000 modules are engineered to recognized data center reliability tiers and enclosure protection ratings, with full technical documentation available for project design.
Tier II-IV Design Reference
Module architecture supports Tier II or Tier III baseline reliability, expandable to Tier IV depending on redundancy configuration.
Enclosure & Surge Protection
IP20-rated cabinets with Class B and C surge protection on the integrated UPS, precision distribution cabinet and smart busway.
Technical Documentation
Installation drawings, single-line power diagrams and monitoring system documentation provided to support project design and commissioning.
Get a Custom MC6000 Data Center Quote
Tell us your target IT load, footprint and reliability tier — our engineering team will configure an MC6000 module and respond with a proposal.