Kexingyu E-Power Group
Home » Products » Modular Data Centers » MC6000 Micro-Module Data Center

Modular Data Centers

MC6000 Micro-Module Data Center

The MC6000 is a factory-standardized micro-module data center that integrates IT cabinets, power distribution, precision cooling, cabling, security and intelligent monitoring into a single deployable system. Configurable as single-row or dual-row sealed cold/hot aisle modules from 3 to 48 cabinets, MC6000 supports IT loads up to 310kW per module and reaches Tier IV reliability, with a typical build-to-commission cycle of just 3-6 weeks.

Engineered for Reliable, Efficient Data Center Deployment

MC6000 combines standardized modular construction with intelligent monitoring and high-density power and cooling, giving operators a data center infrastructure platform that is fast to deploy, simple to maintain and efficient to run.

STD

Standardized Modular Architecture

Highly generic components and standardized module design avoid system design errors and simplify sourcing and maintenance.

RLB

Fault-Tolerant, Low-Interference Design

System-level fault tolerance combined with strong/weak current separation reduces electromagnetic interference and improves reliability.

3-6W

3-6 Week Delivery

Standardized modular design supports mixing sizes and power ratings, enabling product handover in as little as 3-6 weeks.

MON

Intelligent Micro-Module Monitoring

A unified monitoring platform manages in-module power, environment, security and fire systems, with precision metering for accurate energy analysis.

EFF

High-Density Integrated Power & Cooling

Industry-leading power density and efficiency with sealed cold/hot aisle containment, available in single-row or dual-row configurations to isolate airflow and eliminate hot spots.

PUE

Low PUE, Scalable Expansion

Sealed aisle containment keeps PUE lower than traditional server rooms, while modules can be expanded incrementally as capacity needs grow.

OEM & ODM Capabilities

Every MC6000 module is configured to project requirements — from aisle layout and cabinet count to power topology and cooling type — and delivered under the customer’s own brand.

CFG

Custom Aisle & Cabinet Configuration

Single-row or dual-row sealed aisle layouts, 3-24 cabinets per single row or 6-48 per dual row, sized to available floor space.

PWR

Custom Power Topology

Integrated UPS, external precision distribution cabinet, or smart busway configurations, in AC or DC power systems.

CLG

Custom Cooling Type

Air-cooled or chilled-water in-row cooling, sized from 12kW to 70kW per unit to match module heat load.

BAT

Battery & Backup Options

Lead-acid or lithium-ion battery support, deployed as battery cabinet, rack or box, with 15-240 minute backup configured to project needs.

MGT

Monitoring & Software Integration

Unified monitoring platform can be configured to integrate with the customer's existing building or network management systems.

BRD

Branded Enclosure & Nameplate

Exterior panels, door fascia and display branding customized to the customer's own product identity for OEM/ODM programs.

Technical Specifications

MC6000 configuration and parameters covering module dimensions, power system, cooling and reliability rating.

General Specifications
Micro-Module Type Air-cooled or chilled-water in-row cooling, single-row or dual-row sealed cold/hot aisle containment
Channel Door Motorized bi-directional sliding full-glass door
Dual-Row Sealed Aisle (L x W x H) L x 3600 x 2550/2750mm; L x 3400 x 2550/2750mm; L x 3200 x 2550/2750mm (L ≤ 15m)
Single-Row Sealed Aisle (L x W x H) L x 2465 x 2550/2750mm; L x 2365 x 2550/2750mm; L x 2265 x 2550/2750mm (L ≤ 15m)
Cabinets per Module Single-row: 3-24; Dual-row: 6-48
Power System AC 380/400/415Vac, 50/60Hz, 3Ph+N+PE; DC -48/240/336Vdc, positive & negative +PE
Operating Environment Ultra-low temperature: -40~45°C; T1 condition: -25~45°C; T3 condition: -5~45°C
Reliability Tier & Altitude Tier II-III, expandable to Tier IV; derate above 1000m altitude
Battery support: lead-acid or lithium-ion, deployed as battery cabinet, rack or box; backup time 15-240 minutes configurable to project requirements.
Performance Snapshot
Parameter Value Notes
IT Load per Module ≤200kW / ≤310kW Integrated UPS or busway / precision distribution cabinet
Integrated UPS Rating 25-200kVA Efficiency ≥96%
Battery Backup Time 15-240 min Configured to project needs
Reliability Tier Tier II-IV Expandable design
IP20 Cabinet Tier II-IV PUE Optimized 3-6 Week Delivery
Subsystem Dimensions Input Power Capacity Rating Refrigerant / Protection Remarks
IT Cabinet600/800 x 1200 x 2000/2200mm; 600/800 x 1100 x 2000/2200mm; 600/800 x 1000 x 2000/2200mm42U / 47U usable spaceIP20Standard rack cabinet
Integrated UPS (built-in)380/400/415Vac, 50/60Hz, 3Ph+N+PE25-200kVAEfficiency ≥96%, PF full load >0.99 / half load >0.98Surge protection Class B, C
Precision Distribution Cabinet (external UPS)380/400/415Vac, 50/60Hz, 3Ph+N+PEInput breaker 160A/250A/400A/630ASurge protection Class B, C
Smart Busway380/400/415Vac, 50/60Hz, 3Ph+N+PEInput breaker 160A/250A/400A/630AIT output 40A/1P, 40A/3P, 63A/3P
Air-Cooled In-Row ACIndoor unit 300/600 x 1000/1100/1200 x 2000/2200mmAC 380/400/415Vac, 50/60Hz (optional DC 240/336Vdc)12-60kWRefrigerant R410A, optional pump
Chilled-Water In-Row ACIndoor unit 300/600 x 1000/1100/1200 x 2000/2200mmAC 380/400/415Vac, 50/60Hz, 3Ph+N+PE20-70kWCoolant: water / ethylene glycol solution

Construction & Configuration

MC6000 integrates six core subsystems in a factory-standardized enclosure, built for fast on-site assembly and simplified maintenance.

Numbered construction diagram of MC6000 micro-module showing cabinet, power, cooling and monitoring components
01

Micro-Module Enclosure & Sealed Aisle

Single-row or dual-row cold/hot aisle containment with motorized sliding glass channel doors.

02

IT Cabinets

42U or 47U usable rack space, 3-24 cabinets per single row or 6-48 per dual row, IP20 protection.

03

Integrated Power System

Integrated UPS, external precision distribution cabinet or smart busway, rated 25-200kVA.

04

In-Row Cooling System

Air-cooled (12-60kW) or chilled-water (20-70kW) in-row units matched to module heat load.

05

Fire Suppression & Early Warning (Optional)

Extra-early smoke detection and fire pre-warning available as an optional add-on module.

06

Intelligent Monitoring & Management Platform

Unified monitoring of power, environment, security and fire systems, with precision energy analysis.

Standards & Test Documentation

MC6000 modules are engineered to recognized data center reliability tiers and enclosure protection ratings, with full technical documentation available for project design.

RELIABILITY

Tier II-IV Design Reference

Module architecture supports Tier II or Tier III baseline reliability, expandable to Tier IV depending on redundancy configuration.

PROTECTION

Enclosure & Surge Protection

IP20-rated cabinets with Class B and C surge protection on the integrated UPS, precision distribution cabinet and smart busway.

DOCUMENTATION

Technical Documentation

Installation drawings, single-line power diagrams and monitoring system documentation provided to support project design and commissioning.

PROJECT INQUIRY

Get a Custom MC6000 Data Center Quote

Tell us your target IT load, footprint and reliability tier — our engineering team will configure an MC6000 module and respond with a proposal.