Modular Data Centers
MC2000 Compact Modular Data Center
The MC2000 packages power distribution, UPS, cooling, cabling and monitoring into a single cabinet or a row of factory-preassembled cabinets, ready for use immediately after arrival on site. With three aisle containment options, support for 1-12 IT cabinets and a built-in 10.1-inch touchscreen management system, MC2000 is purpose-built for small and mid-size data rooms that need fast deployment without sacrificing reliability.





Built for Simple, Efficient Small-Format Deployment
MC2000 brings the same standardized, factory-integrated approach as larger modular data centers down to a single-cabinet or multi-cabinet scale, with flexible containment, power and monitoring options.
Standardized Modular Cabinets
Highly generic sub-modules with low site requirements — cabinets connect quickly on arrival, ready to use with minimal on-site work.
Single-System Monitoring
One monitoring platform manages power, cooling and environment, so operators never have to switch between multiple interfaces.
Three Containment Options, Leading PUE
Sealed cold/hot aisle, sealed cold aisle, or natural convection — chosen per site to maximize cooling utilization and efficiency.
Flexible Expansion & Power Options
Supports rack-mount or in-row air conditioning, lead-acid or lithium-ion batteries, and single or dual power feed configurations.
Seismic-Tested, Fault-Tolerant Design
Standardized architecture with strong/weak current separation, tested to withstand magnitude 8-9 seismic activity.
Smart Touchscreen Monitoring
Built-in 10.1-inch industrial touchscreen plus mobile app and network access for remote, multi-site centralized monitoring.
OEM & ODM Capabilities
MC2000 is configured per project — cabinet count, containment type, cooling method and power architecture — and delivered under the customer’s own brand.
Custom Cabinet Count
From a single cabinet up to a 12-cabinet row, sized to overall footprint (600-7800)mm wide x 1400mm deep x 2000mm high.
Custom Containment Type
Sealed cold/hot aisle, sealed cold aisle, or natural convection layout selected to match site conditions.
Custom Cooling Type
Rack-mount air conditioning (5U/8U/10U) or in-row air conditioning, sized from 3.5kW to 25kW.
Custom UPS Configuration
N, N+1 or 2N redundancy, UPS capacity from 3kVA to 30kVA, single or three-phase input.
Custom Battery Options
Lead-acid or lithium-ion batteries, deployed as battery pack, cabinet or rack, with 15-240 minute backup time.
Custom Monitoring Integration
Modbus TCP/IP protocol supports integration with the customer's own upper-level monitoring platform and mobile app.
Technical Specifications
MC2000 configuration and parameters covering cabinet layout, power system, cooling and monitoring.
| Cabinet Configuration | Cabinet-based, single-row aisle |
|---|---|
| Aisle Containment Options | Sealed cold/hot aisle (recommended); sealed cold aisle; natural convection |
| Protection Rating | IP50 (glass door) |
| Operating Temperature | -20°C ~ +45°C |
| IT Cabinet Count | 1-12 |
| Max IT Load | 50kW total; 7kW per cabinet maximum power density |
| Installation | Concrete floor or raised floor |
| Overall Dimensions (W x D x H) | (600-7800) x 1400 x 2000mm |
| Parameter | Value | Notes |
|---|---|---|
| UPS Capacity | 3-30kVA | N, N+1 or 2N configuration |
| UPS Efficiency | ≥95% | Output power factor 1 |
| Battery Backup | 15-240 min | Lead-acid or lithium-ion |
| Cooling Capacity | 3.5-25kW | Rack-mount or in-row AC |
| Subsystem | Dimensions / Type | Input Power | Capacity | Rating | Refrigerant / Protection | Remarks |
|---|---|---|---|---|---|---|
| Rack-Mount AC | 5U / 8U / 10U | 220/380Vac | 3.5kW / 7.5kW / 12.5kW | Airflow: front supply, rear return | Refrigerant R410A | N, N+1 configuration |
| In-Row AC | 300mm width | 220/380Vac | 25kW | Sensible heat ratio 1 | Refrigerant R410A | — |
| UPS System | — | Single-phase 220/230/240Vac; three-phase 380/400/415Vac | 3-30kVA | Efficiency ≥95%, output PF 1 | Surge protection Class C | N, N+1, 2N |
| Battery System | Battery pack / cabinet / rack | — | Backup 15-240 min | — | Lead-acid or lithium-ion | — |
| PDU | Standard or intelligent | — | — | IEC or GB plug support | — | — |
| Monitoring System | 10.1" industrial touchscreen | — | — | Modbus TCP/IP, web access, mobile app | — | Multi-site centralized monitoring |
Construction & Configuration
MC2000 integrates six core subsystems inside a factory-preassembled cabinet, ready to power up on arrival.
Cabinet & Aisle Containment
Single or multi-cabinet row with sealed cold/hot aisle, sealed cold aisle, or natural convection layout, IP50 glass door.
Power Distribution & UPS
Integrated UPS rated 3-30kVA in N, N+1 or 2N configuration, single or dual power feed supported.
Cooling System
Rack-mount air conditioning (5U/8U/10U) or in-row air conditioning, sized 3.5-25kW.
Battery Backup
Lead-acid or lithium-ion battery pack, cabinet or rack, with 15-240 minute backup time.
Fire Suppression System
Dual-interlock smoke and heat detection triggers heptafluoropropane gas suppression.
Intelligent Monitoring & Ambient Lighting
10.1-inch touchscreen management with mobile app access, plus temperature-linked LED ambient lighting for status and maintenance.
Standards & Test Documentation
MC2000 cabinets are seismic-tested and enclosure-rated for reliable operation, with full technical documentation available for project design.
Seismic-Tested Design
Standardized cabinet architecture tested to withstand magnitude 8-9 seismic activity while remaining energized.
Enclosure & Surge Protection
IP50-rated glass cabinet doors with Class C surge protection on the integrated UPS system.
Technical Documentation
Installation drawings, power single-line diagrams and Modbus TCP/IP monitoring protocol documentation provided to support project design and integration.
Get a Custom MC2000 Data Center Quote
Tell us your target IT load, cabinet count and site constraints — our engineering team will configure an MC2000 system and respond with a proposal.