Special Wire and Cable > Submersible Pump Cable
JHS Deep-Well Waterproof Cable (0.6/1kV, 1.6/3kV)
The JHS Deep-Well Waterproof Cable is engineered for submersible pumps, underwater VFD-to-pump connections, underwater lighting, and float switch wiring. Verified for continuous immersion depths up to 500m in dry, damp, wet, and outdoor conditions (not rated for hazardous areas). EPDM core insulation, an inner waterproof rubber sheath, and an outer PUR/neoprene blue jacket protect against water ingress, while optional steel wire or Kevlar strain relief supports deep-well hanging installations. Available at 0.6/1kV and 1.6/3kV, dual CE and UL certified, and open to OEM/ODM production in custom core counts, lengths, and reel packaging.





Key Features
Purpose-built for deep-well submersible pump systems, with verified deep-immersion performance and optional strain relief for hanging installations.
Verified 500m Immersion Depth
Tested for continuous submersion in dry, damp, wet, and outdoor conditions up to 500m deep.
Pump & VFD Connections
Designed for submersible pumps, underwater VFD-to-pump wiring, lighting, and float switches.
EPDM Core Insulation
Ethylene propylene diene rubber insulation resists water absorption and maintains flexibility.
Dual-Layer Sheath
Inner waterproof rubber sheath plus an outer PUR/neoprene jacket for layered water protection.
Optional Strain Relief
Steel wire or Kevlar strain relief available for deep-well hanging installations.
Dual Certified
CE and UL certification supports distribution across both EU and North American markets.
OEM & ODM Capabilities
Sourced directly from a certified manufacturing partner, available for bulk and private-label programs tailored to pump and water equipment distributors.
Custom Core Count & Section
Configurable conductor count and cross-sectional area per project specification.
Strain Relief Option
Steel wire or Kevlar strain relief selectable for deep-well hanging installations.
Custom Length & Reel Packing
Cut lengths, coils, or reel packaging configured for well and pump installation projects.
Standards Compliance
Production aligned to DIN VDE, BS, IEC, CE, and UL requirements for target export markets.
Private Labeling
Branded packaging and reel labeling available for distributor and OEM programs.
Bulk & Container Orders
Production scaled for container-load orders with consistent quality control.
Technical Specifications
Core electrical and construction parameters for the JHS Deep-Well Waterproof Cable, based on manufacturer test data.
| Conductor | Fine stranded bare copper, DIN VDE 0295 Cl 5 / BS 6360 Cl 5 / IEC 60228 Cl 5 |
|---|---|
| Core Insulation | EPDM (ethylene propylene diene rubber) |
| Core Color Coding | 3-core and above include green/yellow ground wire |
| Cabling | Cores stranded in layers with optimal lay length |
| Strain Relief | Steel wire / Kevlar (optional) |
| Inner Sheath | Waterproof rubber |
| Outer Sheath | PUR / neoprene (polychloroprene rubber) |
| Outer Sheath Color | Blue |
| Parameter | Value | Reference |
|---|---|---|
| Underwater Temp. Limit | +40°C recommended / +60°C max | Submerged |
| Fixed Install Temp. | -40°C to +80°C | Ambient |
| Static Load | Total cross-section × 200 N/mm² | — |
| Min. Insulation Resistance | 20 MΩ × km | — |
| Layer | Material | Standard | Function | Notes |
|---|---|---|---|---|
| Conductor | Fine stranded bare copper | DIN VDE 0295 Cl 5 / BS 6360 Cl 5 / IEC 60228 Cl 5 | Current-carrying core | Configurable per project (core count/cross-section) |
| Core Insulation | EPDM | — | Electrical insulation, water-resistant | 3-core and above include green/yellow ground |
| Cabling | — | — | Layered stranding at optimal lay length | Configurable per project |
| Strain Relief | Steel wire or Kevlar | — | Mechanical support for hanging installation | Optional |
| Inner Sheath | Waterproof rubber | — | Primary water barrier | — |
| Outer Sheath | PUR / neoprene | — | Mechanical & water barrier protection | Blue |
| Certification | — | CE, UL | Compliance | Dual EU/US certified |
Construction & Configuration
Layer-by-layer construction of the JHS Deep-Well Waterproof Cable, from conductor to outer sheath.
Conductor
Fine stranded bare copper conductor complying with DIN VDE 0295 Cl 5, BS 6360 Cl 5, IEC 60228 Cl 5.
Core Insulation
EPDM insulation applied to each conductor, color-coded with green/yellow ground on 3-core and above.
Cabling & Strain Relief
Cores stranded in layers at optimal lay length, with optional steel wire or Kevlar strain relief for hanging installations.
Inner Sheath
Waterproof rubber inner sheath forms the primary water barrier.
Outer Sheath
Blue PUR/neoprene outer sheath for mechanical and water barrier protection.
Certification & Compliance
Rated 0.6/1kV and 1.6/3kV, verified to 500m submersion depth, dual CE/UL certified.
Standards & Test Documentation
Manufactured to recognized European conductor standards, with verified deep-immersion performance and dual-market compliance certification.
DIN VDE 0295 / BS 6360 / IEC 60228 Cl 5
Defines the fine stranded bare copper conductor class used throughout the cable construction.
500m Immersion Depth
Tested for continuous submersion in dry, damp, wet, and outdoor conditions up to 500m deep; not for hazardous areas.
CE & UL Dual Certification
Certified for both EU and North American markets, supporting cross-border distribution and OEM programs.
Need Deep-Well Cable for Your Pump System?
Send your voltage, core count, and length requirements — our team will confirm OEM/ODM options and lead time.