Kexingyu E-Power Group
Home » Cables & Wires » Special/Industrial Cables » High & Low Temperature Resistant Cable » SiHF-C-Si Multi-Core Double-Sheath Shielded Silicone Rubber Cable

Special Wire and Cable > High & Low Temperature Resistant Cable

SiHF-C-Si Multi-Core Double-Sheath Shielded Silicone Rubber Cable

The SiHF-C-Si is a specialized multi-core silicone rubber cable rated below 180°C, engineered for high-temperature and low-temperature regions where cable insulation must tolerate significant temperature swings. Built with a tinned copper conductor, silicone rubber insulation, an inner silicone sheath, and a tinned copper wire braid shield (approximately 85% coverage) beneath a silicone outer jacket, it delivers reliable EMI shielding alongside excellent chemical and thermal resistance. Halogen-free and low-smoke, it is widely used in the steel production, aviation, shipbuilding, cement, glass, ceramics, and power generation industries, with dual CE and UL certification. For fixed installation only — not suitable for outdoor use.

Key Features

A shielded, double-sheathed silicone rubber cable engineered for clean signal transmission in extreme-temperature industrial environments.

-60/180

Wide -60°C to +180°C Range

Rated for continuous use from -60°C to +180°C, with short-term capability up to +220°C.

SHD

Tinned Copper Braid Shield

Tinned copper wire braid shield at approximately 85% coverage delivers reliable EMI protection.

DBL

Double-Sheath Construction

Inner silicone sheath plus outer silicone jacket provide added mechanical and thermal protection.

CHM

Chemical & Oil Resistant Silicone

Silicone jacket resists heat, chemical corrosion, oil, and acid exposure in harsh industrial settings.

HFR

Halogen-Free, Low-Smoke

Halogen-free construction per DIN VDE / EN / IEC standards, especially suited for power plant use.

APP

Heavy Industry Applications

Used in steel production, aviation, shipbuilding, cement, glass, ceramics, and power generation plants.

OEM & ODM Capabilities

Configurable core counts, conductor gauges, and colors to match your shielded signal transmission requirements.

CORE

Wide Core Count Range

Available from 2-core to 25-core configurations, across AWG20 to AWG4 conductor sizes.

CLR

Standard Color Coding

Conductor color coding per DIN VDE 0293-308, or black conductors with continuous white numbering.

GND

Grounding Conductor Option

3-core and above configurations include a yellow-green grounding conductor as standard.

SHD

Shield Coverage Options

Standard ~85% tinned copper braid coverage, with alternative coverage levels available on request.

JKT

Jacket Color Options

Red or brown silicone jacket options, with double-sheath construction.

QTY

Small-Batch & Volume Production

From prototype runs to bulk orders, with quick-turn production available for standard configurations.

Technical Specifications

Available across a wide range of core counts and conductor sizes. Full dimensional table below.

General Specifications
ConductorTinned copper, per DIN VDE 0295 cl.5, BS 6360 cl.5, IEC 60228 cl.5
InsulationSilicone rubber insulation
Conductor Color CodingPer DIN VDE 0293-308, or black conductor with continuous white numbering
2-CoreBrown / Blue
3-Core and AboveIncludes yellow-green grounding conductor
Inner SheathSilicone inner sheath
WrapPresent
Shield / BraidTinned copper wire braid, approx. 85% coverage
Outer JacketSilicone
Jacket ColorRed / Brown
Rated Voltage300/500 V
Test Voltage2000 V
Dynamic Bend Radius7.5 × cable diameter (φ)
Fixed Installation Radius4 × cable diameter (φ)
Operating Temperature Range-60°C to +180°C
Short-Term Peak Temperature+220°C
Flame ResistanceIEC 60332.1
Insulation Resistance20 MΩ × km
Radiation Resistance20 × 10⁶ cJ
CertificationDual certified — CE (EU) and UL (North America)
For fixed installation in open air or ventilated ducting/piping systems only — not suitable for outdoor use. Mechanical performance may degrade above 90°C in enclosed, unventilated air.
Performance Snapshot
Temp. Range-60°C to +180°C
Peak Temp.+220°C short-term
Rated Voltage300/500V
CertificationsCE + UL
-60°C to 180°C
Shielded
Halogen-Free
CE
UL
Multi-Core
OEM/ODM
AWG Core Count Conductor Cross-Section (mm²) Nominal OD (mm) Copper Weight (kg/km)
2020.258.755.5
2030.258.960.8
2040.259.466.5
2050.251081.6
2070.2510.592.2
20100.2513.1124
20120.2513.4134.4
20160.2514.6170.2
20180.2515.1181
20250.2519.4230.1
1820.759.261.4
1830.759.569.1
1840.7510.186.7
1850.7510.895.2
1870.7511.6113.3
18100.7514.4165.2
18120.7514.7180.3
18160.7516.5212.2
18180.7517.3282.1
18250.7522.1297.4
17219.566.7
17319.786.2
174110.496.8
175111.3108.3
177112141.2
1710114.9190
1712115.2209.8
1716117251.8
1718117.8297.4
1725123329
1621.510.787.7
1631.511.2103.5
1641.511.8131.7
1651.513.3148.5
1671.514.3193.4
16101.517.7268.5
16121.518298.4
16161.520.1362.3
16181.520.9394
16251.524.1488.2
1422.512.1122.3
1432.512.9147.7
1442.514.2188.6
1452.515.3214.9
1472.516.9265.7
124417.1294
125419.4374
104618.8449
105621.2563
841025.7759
641628.41180
4425351810

Construction & Configuration

A double-sheathed, tinned-copper-shielded silicone rubber construction built for clean signal transmission in extreme temperature environments.

Numbered construction diagram of SiHF-C-Si multi-core shielded cable layers
01

Conductor

Tinned copper conductor per DIN VDE 0295 cl.5, BS 6360 cl.5, IEC 60228 cl.5.

02

Insulation

Silicone rubber insulation for high dielectric and thermal performance.

03

Inner Silicone Sheath

Silicone inner sheath bundles the cores before the shielding layer is applied.

04

Tinned Copper Braid Shield

Tinned copper wire braid at approximately 85% coverage delivers reliable EMI shielding.

05

Silicone Outer Jacket

Red or brown silicone outer jacket resists heat, chemicals, and oil exposure.

Standards & Test Documentation

Manufactured and tested to recognized international halogen-free and flame-resistance standards.

Halogen-Free Standard

DIN VDE / EN / IEC Compliance

Halogen-free per DIN VDE 0482 part 267 / EN 50267-2-1 / IEC 60754-1 (equivalent to DIN VDE 0472 part 815).

Flame Resistance Standard

Non-Flame-Propagating Test

Tested per DIN VDE 0482 part 265-2-1 / EN 50265-2-1 / IEC 60332-1 (equivalent to DIN VDE 0472 part 804, method B).

Certifications

Dual CE & UL Certification

Certified to both EU (CE) and North American (UL) requirements, supporting global project deployment.

Project Inquiry

Need SiHF-C-Si Shielded Silicone Cable for Your Project?

Share your core count, AWG, jacket color, and certification requirements — our team will provide technical specifications and pricing within 24 hours.