Kexingyu E-Power Group
Home » Cables & Wires » Special/Industrial Cables » Weather-Resistant Cable » Weather-Resistant Cable (Plateau Region)

Special Wire and Cable > Weather-Resistant Cable

Weather-Resistant Cable (Plateau Region)

Engineered for high-altitude plateau regions worldwide, this weather-resistant DC cable serves photovoltaic power systems as the connection cable between generation equipment leads and module string combiners, rated up to DC 1.8kV. Built for intense UV exposure, extreme temperature swings, and multi-decade outdoor service, it delivers a service life of 25 years or more.

Key Features

Engineered for High-Altitude Solar Power Applications

Purpose-built for the intense UV exposure and extreme temperature swings of high-altitude plateau regions worldwide, this cable delivers long-term reliability in photovoltaic power systems.

ALT

Built for High-Altitude Plateau Regions

Designed to withstand the extreme UV, temperature, and weather conditions of plateau regions worldwide.

PV

Rated up to DC 1.8kV

Suited for photovoltaic system generation leads and module string combiner connections.

XLP

125°C Cross-Linked Polyolefin Construction

Irradiation cross-linked polyolefin insulation and jacket provide strong thermal and electrical performance.

UVO

UV, Ozone & Thermal Cycling Resistant

Withstands intense UV exposure, ozone, and rapid temperature swings typical of high-altitude sites.

DUR

25+ Year Service Life

Engineered for long-term outdoor deployment with a rated service life of 25 years or more.

CHM

Optional Chemical Resistance

Additional acid/alkali resistance available for installations in chemically aggressive high-altitude sites.

OEM & ODM Capabilities

Custom-Engineered Plateau Cable Solutions

This cable can be configured in core count and cross-section to match specific photovoltaic system layouts across a range of high-altitude installation sites.

CNT

Custom Core Count (1-60 Cores)

Core count configured within a 1 to 60 core range to match photovoltaic system layout requirements.

SEC

Custom Conductor Cross-Section

Conductor cross-section configured to match current-carrying and voltage drop requirements.

GND

Optional Ground Core

A yellow/green ground protection core can be added to the cable configuration on request.

VLT

Custom Voltage Configuration

Voltage rating configured up to DC 1.8kV to match photovoltaic system requirements.

DOC

Test Report Documentation Support

GB/T test report documentation available to support customer qualification needs.

ENG

Project-Specific Engineering Support

Small-batch prototyping and volume production supported for high-altitude solar power projects.

Technical Specifications

Electrical & Environmental Specifications

Electrical ratings are fixed by conductor size and insulation type, while core count is configurable within a 1 to 60 core range.

General Specifications
Product Type Weather-Resistant Cable (Plateau Region)
Conductor Fine oxygen-free bare/tinned copper wire, multi-strand regular short-lay stranding, per IEC 60228 Cl.6 / VDE 0295 Cl.6
Core Insulation 125°C irradiation cross-linked polyolefin
Core Count 1 to 60 cores
Outer Jacket 125°C irradiation cross-linked polyolefin, black
Rated Voltage Up to DC 1.8kV (photovoltaic systems)
Service Life 25+ years
Application Generation equipment leads and module string combiner connections
Compliance testing is based on IEC 60228 / VDE 0295 conductor standards and GB/T national test protocols; no CE/UL certification data was provided for this product.
Performance Snapshot
Attribute Rating Notes
UV & Ozone Resistance Dedicated test protocols passed High-altitude/high-UV rated
Flame Retardance GB/T 18380.12-2008 Vertical burning test
Acid/Alkali Resistance GB/T 2951.21-2008 tested Optional for chemically aggressive sites
Service Life 25+ years —
High-Altitude Rated DC 1.8kV 125°C Cross-Linked 25-Year Life
Layer Material Standard Function Notes
ConductorFine oxygen-free bare/tinned copper wireIEC 60228 Cl.6 / VDE 0295 Cl.6Carries electrical currentMulti-strand, regular short-lay stranding
Core Insulation125°C irradiation cross-linked polyolefin—Electrical & thermal insulation—
Core Count1 to 60 cores—Configurable circuit countPer project layout
Outer Jacket125°C irradiation cross-linked polyolefin—UV, ozone & weather resistanceBlack, per product imagery

Construction & Configuration

Cross-Linked Polyolefin Cable Structure

The plateau region cable pairs a fine oxygen-free copper conductor with 125°C cross-linked polyolefin insulation and jacket, configurable from 1 to 60 cores.

Numbered construction diagram of plateau region cable layers
CDR

Fine Oxygen-Free Copper Conductor

Fine oxygen-free bare or tinned copper wire, multi-strand with regular short-lay stranding, per IEC 60228 / VDE 0295 Class 6.

XLP

125°C Cross-Linked Polyolefin Insulation

Irradiation cross-linked polyolefin insulation provides strong thermal and electrical performance.

CNT

Configurable 1-60 Core Count

Core count can be configured from 1 to 60 to match photovoltaic system connection requirements.

JKT

125°C Cross-Linked Polyolefin Outer Jacket

The same cross-linked polyolefin compound forms the outer jacket, providing UV and weather resistance.

UVR

UV & Ozone Resistant Construction

Materials and construction are verified against dedicated UV and ozone exposure test protocols.

DUR

25+ Year Rated Service Life

Materials and construction are engineered to support a service life of 25 years or more in outdoor deployment.

Standards & Test Documentation

Standards, Testing & Durability

This cable’s conductor complies with IEC 60228 / VDE 0295 Class 6, and its materials are verified through GB/T environmental test protocols for long-term high-altitude service.

CONDUCTOR STANDARD

IEC 60228 & VDE 0295 Class 6 Compliance

Conductor construction complies with IEC 60228 Class 6 and VDE 0295 Class 6 for fine stranded copper wire.

TEST STANDARDS

GB/T Environmental & Chemical Testing

Tested per GB/T 2951 series (thermal, humidity, low-temperature impact & bending, acid-alkali) and GB/T 18380.12-2008 vertical flame testing.

DURABILITY

25+ Year High-Altitude Service Life

Engineered to withstand intense UV exposure, ozone, and extreme temperature cycling typical of high-altitude plateau regions worldwide.

PROJECT INQUIRY

Ready to Discuss Your High-Altitude Cable Project?

Share your core count, voltage, and installation site details and our team will propose a plateau-rated cable configuration.