Kexingyu E-Power Group

LOW-VOLTAGE POWER CABLE

YJV Low-Voltage XLPE Power Cable 0.6/1kV

Copper-conductor, XLPE-insulated and PVC-sheathed power cable (YJV) for low-voltage distribution enquiries. Send core count, cross-section, quantity and destination for review and quotation.

Modern XLPE insulated power cable product photo

Construction & Features

YJV is an XLPE-insulated, PVC-sheathed power cable used for fixed low-voltage distribution. The points below follow the manufacturer catalogue; exact construction and ratings are checked against the specification you send.

Cu

Copper conductor

A copper conductor forms the core. State the core count and nominal cross-section required for your distribution circuits.

XLPE

XLPE insulation

Cross-linked polyethylene insulation is used on the conductor. Confirm the rated voltage and any test requirements with your enquiry.

PVC

PVC sheath

A PVC outer sheath protects the assembly. Tell us the installation context (indoor, tunnel or cable trench) and any armour requirement.

Catalogue Specifications (YJV, 0.6/1kV)

The values below are transcribed from the manufacturer 2023 catalogue low-voltage section. They describe the catalogue basis, not a confirmed offer; final specifications are confirmed in the quotation.

ParameterCatalogue Data
DesignationYJV — XLPE-insulated, PVC-sheathed power cable
Rated voltage0.6/1kV (low voltage)
Cross-section, 1 core1.5–630 mm²
Cross-section, 2/3/4/5 core1.5–400 mm² (also 3+2, 3+1, 4+1)
Insulation / sheathXLPE insulation / PVC sheath
Conductor temperature≤90℃ continuous; ≤250℃ short circuit (5 s)
Minimum bending radiusconfirm against the selected cable construction and installation requirements.
StandardGB/T 12706.1-2008 (as listed in the 2023 catalogue)

Other sizes on enquiry. Final specifications and required documentation are confirmed in the quotation.

Details for Your Quotation

Send your requirements for the points below. Available sizes, documentation and commercial terms are confirmed against your enquiry.

ItemInformation to Include
Core count & cross-sectionState core count and nominal cross-section in mm².
Rated voltageConfirm 0.6/1kV or the voltage required by your system.
ArmourState whether an armoured variant (for example YJV22) is required.
PackingState preferred reel or drum format and length per pack.
QuantityProvide estimated per-order and annual quantity.
DocumentationName the standard and any test reports required with the offer.
DestinationConfirm destination market and import documentation needs.

Standards & Documentation

Standards and test documents are reviewed against the specification for your market or project.

  • State the cable standard required in your market and provide the tender clause if available.
  • Specify which tests or reports must accompany the offer (for example conductor resistance, insulation thickness or voltage withstand).
  • Confirm the required certification route and whether third-party witness testing is needed.
  • Send the accepted document format and language for technical data and labelling.

Frequently Asked Questions

What information should I include in a YJV enquiry?
Send the core count, cross-section, rated voltage, quantity and destination country. Adding the applicable standard or a purchase list helps us review your requirement.
Which cross-sections are covered at 0.6/1kV?
The catalogue lists 1.5–630 mm² for single core and 1.5–400 mm² for multi-core constructions. Confirm your required size with your enquiry.
Do you offer an armoured version?
The catalogue lists armoured variants such as YJV22. State your armour and installation requirements so they can be reviewed.
Can ratings and documents be checked before quotation?
Ratings and documentation are reviewed against the specification you provide. Include the required standard and test documents with your enquiry.
How is packing handled for wholesale orders?
Let us know your preferred reel or drum format, pack length and labelling needs. These points are reviewed together with your enquiry.
How do we move from enquiry to quotation?
Send your requirements using the contact form. The construction and documents you provide are reviewed before a quotation is prepared.

Request a YJV Power Cable Quotation

Send your core count, cross-section, rated voltage, quantity and destination market. We will review the specification and reply with a quotation.