Kexingyu E-Power Group
Home » Batteries & Energy Storage » High-Voltage Backup Lithium-ion Battery System (EUB Series)

Cables & Wiring Systems

High-Voltage Backup Lithium-ion Battery System (EUB Series)

Modular high-voltage lithium-ion battery system for high-voltage UPS backup power, covering 192V to 614.4V platforms with 50Ah to 314Ah LFP cells.

Key Features

Modular architecture, cell platform range and communication capabilities of our EUB series.

EUB

Modular High-Voltage Architecture

Battery modules, a high-voltage box and a cabinet system combine to deliver 192V to 614.4V backup platforms for high-voltage UPS.

50-314

50Ah to 314Ah Cell Options

Small-rate (2C), high-rate (6C), 102Ah and 314Ah cell platforms cover short-burst to extended-duration backup needs.

3000

Long Cycle Life

LFP cells rated for ≥3000 cycles (0.5CC/1CD) on most platforms, and up to ≥8000 cycles on the 314Ah system.

CAN

RS485/CAN Communication

Every module, box and system communicates over RS485/CAN for integration with centralized monitoring platforms.

COMPAT

Broad UPS Compatibility

Configurations are matched to specific high-voltage UPS series so systems integrate with your existing UPS lineup.

UNMAN

Unattended, Integrated Operation

Intelligent centralized monitoring and battery management support unattended, energy-saving operation.

OEM & ODM Capabilities

Custom voltage platform, capacity, cabinet configuration and communication protocol tailored to your project.

VOLT

Custom Voltage Platform

192V to 614.4V voltage platforms configured to match your specific UPS model.

CAP

Custom Capacity & Backup Time

50Ah, 102Ah, 314Ah or custom capacity cells selected to meet your required backup duration.

CAB

Custom Cabinet Configuration

Cabinet dimensions and standard box count produced to fit your installation footprint.

COMM

Communication Protocol Integration

RS485/CAN protocol and data mapping configured for your monitoring or building management system.

LOGO

Custom Branding & Marking

Customer logo and product marking printed to your brand specification.

MOQ

Sampling & Volume Production

Small-batch sampling for qualification followed by scalable volume production once specifications are confirmed.

Technical Specifications

General specifications, platform snapshot, and full data by module, high-voltage box and system across all 4 capacity/rate platforms.

General Specifications
Battery Type LFP (Lithium Iron Phosphate)
Voltage Platforms 192V, 204.8V, 358.4V, 384V, 409.6V, 460.8V, 512V, 537.6V, 614.4V
Cell Capacity Options 50Ah (2C), 50Ah (6C), 102Ah, 314Ah
Communication RS485/CAN
IP Rating IP20
Cycle Life ≥3000 (0.5CC/1CD) or ≥8000 (0.5CC/0.5CD) on the 314Ah system
Operating Temperature (Discharge) -20℃ to 60℃
Application Backup power for EAST high-voltage UPS and modular power supply systems
Full module, high-voltage box and system-level tables are provided below by capacity/rate platform — contact our team with your required voltage and backup time.
Performance Snapshot
Platform Voltage Range Backup Time
50Ah (2C) 192V / 384V 30min
50Ah (6C) 384V–614.4V 10min
314Ah 204.8V–614.4V 60min
Custom On Request On Request
LFP Chemistry 192V–614.4V RS485/CAN IP20
EUB Series Battery Module — Specifications by Cell Platform
Parameter 50Ah (2C) 50Ah (6C) 102Ah 314Ah
Rated Voltage/V9676.851.251.2
Operating Voltage Range/V75~109.560~87.640~58.440~58.4
Energy/kWh4.83.845.2216.08
Rated Capacity/Ah5050102314
Standard Charge Current/A252550157
Max. Charge Current/A50100100157
Standard Discharge Current/A5050100314
Max. Discharge Current/A100300200314
Weight/kg454548114
Dimension (W×D×H)(mm)465×173×750441×171×600441×129×650440×770×222
Operating Temperature/℃ (Discharge)-20~60-20~60-20~60-20~60
CommunicationRS485/CANRS485/CANRS485/CANRS485/CAN
IP RatingIP20IP20IP20IP20
Battery TypeLFPLFPLFPLFP
EUB High-Voltage Box — Specifications by Current Rating
Parameter Standard Box (250A) High-Current Box (400A)
Voltage Range/V0~8000~800
Current (MAX)/A250400
Weight/kg21.837.10
Dimension (W×D×H)(mm)441×217×545441×217×646
Operating Temperature/℃ (Discharge)-20~60-20~60
Auxiliary Power Supply, Input Voltage Range/VAC85~264/100~24085~264/100~240
Auxiliary Power Supply, Power/W100100
Storage Humidity/%RH≤95≤95
Storage Temperature/℃-40~60-40~60
Altitude/m≤2000≤2000
IP RatingIP20IP20
CommunicationRS485/CANRS485/CAN
System — 50Ah 2C / 27Ah, 192V & 384V Platforms
Model EUB19250R60S1PX-3 EUB38450R120S1P2-Z EUB38450R120S1P2 EUB19227R60S1P-Y
Rated Capacity/Ah50505027
Energy/kWh9.619.219.24.8
Rated Voltage/V192384384192
Operating Voltage Range/V156~219312~438312~438156~219
Standard Charge Current/A25252513.5
Max. Charge Current/A50505027
Standard Discharge Current/A50505081
Number of Standard Box/pc2441
Weight (with cabinet)/kg9020219055
Battery Cabinet Dimension (W×D×H)(mm)600×900×1400600×900×1400600×900×1400442×700×155
Operating Temperature/℃ (Discharge)-20~60-20~60-20~60-20~60
Cycle Life/Times≥3000(0.5CC/1CD)≥3000(0.5CC/1CD)≥3000(0.5CC/1CD)≥3000(0.5CC/1CD)
CommunicationRS485/CANRS485/CANRS485/CANRS485/CAN
IP RatingIP20IP20IP20IP20
Battery TypeLFPLFPLFPLFP
Backup Time/min30303030
Maximum Power/kW20404010
Compatible UPS ModelEA906-EA9020EA9910-EA9940EA89 SeriesEA906-EA9010
System — 50Ah 6C Platform, 384V–614.4V
Model EUB38450R120S1P EUB46050R144S1P EUB46050R144S1P-Z EUB53750R168S1P EUB53750R168S1P-Z EUB61450R192S1P
Rated Capacity/Ah50
Energy/kWh19.223.0423.0426.8826.8830.72
Rated Voltage/V384460.8460.8537.6537.6614.4
Operating Voltage Range/V312~438374.4~525.6374.4~525.6436.8~613.2436.8~613.2499.2~700.8
Standard Charge Current/A25
Max. Charge Current/A100
Standard Discharge Current/A50
Max. Discharge Current/A300
Number of Standard Box/pc566778
Weight (with cabinet)/kg422455470500515545
Battery Cabinet Dimension (W×D×H)(mm)600×900×2000
Operating Temperature/℃ (Discharge)-20~60
Cycle Life/Times≥3000(0.5CC/1CD)
CommunicationRS485/CAN
IP RatingIP20
Battery TypeLFP
Backup Time/min10
Maximum Power/kW115.2138138161.1161.1184.2
Compatible UPS ModelEA89 SeriesEA66 SeriesEA66/EA99 SeriesEA66-100K, EA99proEA66/EA99 SeriesEA89 Series
System — 102Ah Platform, 204.8V–614.4V
Model EUB204102R64S1P EUB358102R112S1P EUB409102R128S1P EUB409102R128S1P-Z EUB512102R160S1P EUB512102R160S1P-Z EUB614102R192S1P
Rated Capacity/Ah102
Energy/kWh20.8936.5641.7841.7852.2252.2262.67
Rated Voltage/V204.8358.4409.6409.6512512614.4
Operating Voltage Range/V166.4~233.6291.2~408.8832.8~467.2832.8~467.2416~584416~584499.2~700.8
Standard Charge Current/A50
Max. Charge Current/A100
Max. Discharge Current/A200
Number of Standard Box/pc4788101012
Weight (with cabinet)/kg375520570585665680765
Battery Cabinet Dimension (W×D×H)(mm)600×900×2000600×900×2200
Operating Temperature/℃ (Discharge)-20~60
Cycle Life/Times≥3000(0.5CC/1CD)
CommunicationRS485/CAN
IP RatingIP20
Battery TypeLFP
Backup Time/min10
Maximum Power/kW40.9613881.9281.92102.4102.4184.2
Compatible UPS ModelEA906-EA9020 SeriesEA89 SeriesEA89 SeriesEA66/EA99 SeriesEA66-100K, EA99proEA66/EA99 SeriesEA89 Series
System — 314Ah Platform, 204.8V–614.4V
Model EUB204314R64S1P EUB358314R112S1P EUB409314R128S1P-Z EUB512314R160S1P EUB512314R160S1P-Z EUB614314R192S1P
Rated Capacity/Ah314
Energy/kWh64.31112.54128.6160.77160.77192.92
Rated Voltage/V204.8358.4409.6512512614.4
Operating Voltage Range/V166.4~233.6291.2~408.8332.8~467.2416~584416~584499.2~700.8
Standard Charge Current/A157
Max. Charge Current/A157
Max. Discharge Current/A314
Number of Standard Box/pc478101012
Weight (with cabinet)/kg640985937115011651695
Battery Cabinet Dimension (W×D×H)(mm)600×850×22001200×1000×1866
Operating Temperature/℃ (Discharge)-20~60
Cycle Life/Times≥8000(0.5CC/0.5CD)
CommunicationRS485/CAN
IP RatingIP20
Battery TypeLFP
Backup Time/min60
Maximum Power/kW64.31112.54128.60160.77160.77192.92
Compatible UPS ModelEA906-EA9020 SeriesEA89 SeriesEA66-100K, EA99pro SeriesEA66/EA99 SeriesEA89 SeriesEA89 Series

Construction & Configuration

How the cell, module, high-voltage box and cabinet come together across the EUB platform.

KEXINGYU EUB battery construction diagram module box cabinet
1

Cell — LFP Chemistry

Lithium iron phosphate cells, in small-rate (2C), high-rate (6C), 102Ah or 314Ah variants, form the energy storage core.

2

EUB Series Battery Module

Cells are assembled into a standard EUB battery module with its own BMS, terminals and communication interface.

3

EUB High-Voltage Box

A high-voltage box (0–800VDC) manages string-level voltage, current and auxiliary power for the connected modules.

4

Battery Cabinet Assembly

Standard boxes are assembled into a rack cabinet sized to the target voltage platform and backup capacity.

5

Communication & Monitoring

RS485/CAN communication links the module, box and system levels to centralized monitoring software.

6

UPS Integration

Each configuration is matched to compatible EAST-format UPS series for straightforward system integration.

Standards & Test Documentation

Verified test records, production drawings and project-specific documentation for technical review and approval.

Safety & Protection

IP20, Multi-Layer Protection

IP20-rated enclosures with integrated BMS protection against overcharge, over-discharge and over-temperature conditions.

Cycle Life

≥3000 to ≥8000 Cycles

Cycle life ranges from ≥3000 cycles (0.5CC/1CD) on most platforms up to ≥8000 cycles (0.5CC/0.5CD) on the 314Ah system.

Environmental Rating

-20℃ to 60℃ (Discharge)

Operating temperature -20℃ to 60℃ on discharge; storage temperature and altitude ratings available in the full datasheet.

Project Inquiry

Request a Quote for High-Voltage Backup Battery Systems

Send us your required voltage platform, capacity, backup time and compatible UPS model. Our team will review the specification and prepare a quotation for your project.