Kexingyu E-Power Group
Home » Transformers & Substations » AC Voltage Stabilizers » WBT Stabilizing Step-Down Transformer Integrated Unit

Transformers & Substations > AC Voltage Stabilizers

WBT Stabilizing Step-Down Transformer Integrated Unit

Most AC stabilizers correct voltage without changing its level — they take a fluctuating 380V in and hold a steady 380V out. The WBT does both jobs in one cabinet: a purpose-built step-down transformer converts three-phase 380V input to three-phase 220V output, while a copper regulation coil and 1017 carbon brush correct fluctuations at the same time, settling within 1 second of a 10% input step change and reacting in as little as 0.05 seconds. That combination is aimed specifically at equipment built for 220V lines running on a 380V supply — precision machine tools, injection molding machines, machining centers, optical curve grinders, laser cutters, and other high-power shop-floor equipment where a separate transformer-plus-stabilizer setup would take up more panel space than a single integrated unit. Optional EMI filtering, surge protection, and RS232/RS485 remote monitoring extend it for unattended, continuous-duty installations.

Key Features

One cabinet, two jobs — voltage conversion and voltage stabilization handled together, with monitoring and protection built in.

3→2

Integrated Step-Down + Regulation

Converts three-phase 380V input to three-phase 220V output while correcting voltage fluctuation in the same unit — no separate transformer needed.

.05S

Fast Response, Fast Settling

Reacts to voltage deviation in as little as 0.05 seconds and settles within 1 second of a 10% step change in input voltage.

BYP

Automatic Bypass

Switches to a direct bypass path when input voltage is stable or during maintenance, keeping connected equipment powered without interruption.

EFF

High Operating Efficiency

Rated above 94% efficiency below 50KVA and above 96% above 100KVA, with noise held to ≤55dB.

RS

Optional Remote Monitoring

RS232/RS485 interfaces support remote control, signaling, and metering for unattended installations (optional).

SPD

Optional Surge & EMI Protection

Lightning/surge protection and EMI filtering are available as configurable add-ons for facilities exposed to grid transients.

OEM & ODM Capabilities

Built-to-order integrated stabilization for machine shops, manufacturers, and B2B distribution partners.

KVA

Configurable Power Rating

Sized to your connected load across the WBT-S platform.

V

Custom Input/Output Voltage

Standard 380V±20% three-phase or 220V±20% single-phase input, with output adjustable within ±5% of rated voltage; special voltage combinations available on request.

OEM

Enclosure & Branding Customization

Custom enclosure finish, nameplate, and packaging available for private-label and distributor programs.

MON

Monitoring Interface Options

RS232/RS485 remote monitoring, EMI filtering, and surge protection configurable as add-ons.

PROT

Adjustable Protection Thresholds

Over-voltage, under-voltage, overload, phase-reversal, and short-circuit thresholds tunable to project specification.

QTY

Small-Batch & Bulk Production

Configurable order quantities from small-batch trial runs to full container bulk production.

Technical Specifications

Full electrical, protection, and performance data for the WBT integrated stabilizing transformer.

General Specifications
Unit Type Integrated Voltage Stabilizer + Step-Down Transformer
Rated Input Voltage 380V ±20% (three-phase) / 220V ±20% (single-phase), special voltages available
Rated Output Voltage Adjustable within ±5% of rated output voltage
Frequency 50Hz/60Hz
Response Time ≤0.05s
Settling Time ≤1s for a 10% step change in input voltage
Operating Efficiency >94% below 50KVA, >96% above 100KVA
Noise Level ≤55dB
Insulation resistance: ≥2MΩ to ground. Dielectric withstand: 2000VAC for 1 minute, no breakdown or flashover. Waveform distortion: none additional. Working mode: rated for long-term unattended continuous operation. Protection: short-circuit cuts output; overload cuts output on an inverse-time delay curve; phase-reversal triggers alarm and automatic cutoff (optional); over-voltage above +10% of rated (adjustable) triggers alarm with ~5s delayed cutoff (alarm-only mode selectable); under-voltage below -15% of rated (adjustable) triggers alarm with ~5s delayed cutoff (alarm-only mode selectable); bypass circuit provides direct pass-through supply when input is stable or during maintenance.
Performance Snapshot
Metric Value Notes
Response Time ≤0.05s Fastest correction stage
Settling Time ≤1s 10% input step change
Efficiency >94% / >96% Below 50KVA / above 100KVA
Noise Level ≤55dB  
380V→220V Step-Down ≤0.05s Response RS232/RS485 Ready Auto Bypass
Model Capacity Rated Current Product Dimensions (L×W×H mm)
WBT-S50KVA50KVA75.9A550×780×1200
WBT-S60KVA60KVA91.1A550×780×1200
WBT-S80KVA80KVA121.5A620×925×1300
WBT-S100KVA100KVA152A620×925×1300
WBT-S120KVA120KVA182.3A620×925×1300
WBT-S150KVA150KVA227.9A700×1025×1390
WBT-S200KVA200KVA303.8A700×1025×1390
WBT-S250KVA250KVA379.8A1000×750×1600
WBT-S300KVA300KVA455.8A1100×800×1800
WBT-S350KVA350KVA531.7A1100×800×1800
WBT-S400KVA400KVA607.7A1200×900×1800
WBT-S500KVA500KVA759.6A1100×1250×2000
WBT-S600KVA600KVA759.6A1100×1250×2000
WBT-S1400KVA1400KVA2127A800×1100×2200 (3-cabinet configuration)

Construction & Configuration

Inside the WBT unit: how a step-down transformer and a copper regulation coil share one cabinet to convert and stabilize voltage together.

Labeled technical diagram of WBT unit internal components
1

Step-Down Transformer Core

Imported silicon-steel sheet core with high-temperature-resistant windings converts three-phase 380V input to three-phase 220V output.

2

Copper Regulation Coil

High-temperature-resistant pure copper winding handles the voltage regulation function alongside the step-down transformer.

3

1017 Carbon Brush Assembly

Selected 1017-grade carbon brush repositions in response to input fluctuation, restoring stable output within about 1 second.

4

Automatic Control & Protection Circuit

Monitors output against short-circuit, overload, phase-reversal, over-voltage, and under-voltage conditions, triggering alarms and cutoffs per configurable thresholds.

5

Bypass Circuit

Provides a direct pass-through supply path when input voltage is stable or during unit maintenance, keeping downstream equipment powered.

6

Optional Monitoring & Protection Add-Ons

RS232/RS485 remote monitoring interface, EMI filtering, and lightning/surge protection available as configurable options.

Standards & Test Documentation

Performance, safety, and documentation support behind every WBT integrated unit.

Performance Standard

Response & Efficiency

Reacts in as little as 0.05 seconds and settles within 1 second of a 10% input step change, with operating efficiency above 94% below 50KVA and above 96% above 100KVA.

Electrical Safety

Insulation & Dielectric Withstand

Insulation resistance ≥2MΩ to ground; rated to withstand 2000VAC for 1 minute without breakdown or flashover.

Documentation

OEM/ODM Technical Support

Full technical datasheets, dimensional drawings, and test reports available on request to support OEM/ODM integration and procurement evaluation.

Get In Touch

Need Voltage Stabilization and Step-Down Conversion in One Unit?

Share your connected 220V equipment load, incoming 380V supply details, and monitoring requirements — our engineering team will configure the right WBT unit for your shop floor.