Kexingyu E-Power Group
Home » Transformers & Substations » AC Voltage Stabilizers » HIS Inverter-Type AC Voltage Stabilizer (5-10KVA)

Transformers & Substations

HIS Inverter-Type AC Voltage Stabilizer

Most voltage stabilizers correct a bad waveform — tapping an autotransformer up or down, or switching triacs on and off — but they’re still working with whatever shape the incoming AC arrives in. The HIS series takes a different approach: incoming AC is first converted to a DC bus, then rebuilt from scratch into a clean 220V sine wave through PWM inversion, the same fundamental principle used in online double-conversion UPS systems. Because the output is regenerated rather than corrected, the HIS can absorb an unusually wide 90-310V input window without the step-lag or contact wear that tap-switching designs eventually show, and its front-panel AVR/Bypass switch gives it a maintenance-safe fallback path that older stabilizer topologies don’t have. Available across a 5-10KVA capacity range, it’s built for site conditions where incoming power is genuinely unpredictable, not just mildly unstable.

Key Features

The HIS series rebuilds — rather than merely corrects — the output waveform, giving it a wider stable operating envelope than tap-switching or SCR-based designs.

INV

Inverter-Rebuilt Sine Wave

Incoming AC is converted to a DC bus and reconstructed through PWM inversion, rather than corrected in place — the same core principle behind double-conversion UPS output.

90V

90-310V Input Window

The widest input tolerance in the AC Voltage Stabilizer line, built to absorb brownouts and surges that tap-switching designs can't ride through.

±2%

220V ±2% Output Precision

Regulation is held tight across the entire input range rather than degrading near the edges of the input window.

A/B

Front-Panel AVR / Bypass Switch

A physical AVR/Bypass changeover lets maintenance staff route power around the unit without an external switchboard.

LCD

Digital Monitoring Display

Front-panel LCD shows live input and output voltage with status indicators, so drift is visible before it becomes a fault.

kVA

5-10KVA Capacity Range

Three frame sizes (HIS-5000 / HIS-8000 / HIS-10000) cover small commercial through light-industrial loads in a compact wall/floor cabinet.

OEM & ODM Capabilities

Every HIS unit ships configured to the project, not pulled from generic stock — capacity, input window, and enclosure details are set at order time.

CAP

Configurable Capacity

Frame size and power rating scaled to your load profile beyond the standard 5-10KVA range.

V-IN

Input Voltage Window Customization

Wider or narrower input tolerance windows available for regions with different grid stability profiles.

ENC

Enclosure & Branding Customization

Cabinet finish, labeling, and panel layout configurable for private-label and distributor branding.

APP

Application-Specific Configuration

Output terminals and mounting orientation adapted to commercial, light-industrial, or site-power use cases.

SET

Adjustable Protection Thresholds

Alarm and cutoff setpoints tuned to project requirements rather than fixed factory defaults.

QTY

Small-to-Large Batch Production

From single-unit prototypes to container-volume orders for distributors and EPC contractors.

Technical Specifications

Core electrical parameters are shared across the HIS series; capacity and frame size scale by model.

General Specifications
Product NameInverter-Type AC Voltage Stabilizer
TechnologyInverter-based (DC bus + PWM), AVR/Bypass switching
Input Voltage90V ~ 310V
Output Voltage220V
Voltage Precision220V ±2%
Rated Input Frequency50Hz
Input Frequency Range40-60Hz
Capacity Range5-10KVA (Configurable beyond standard range)
Full protection thresholds, weight, and certification details are configured per project — contact us with your specifications.
Performance Snapshot
Input Range90-310V
Precision±2%
Capacity5-10KVA
ControlAVR / Bypass
Inverter-Based
Wide-Range Input
Digital Display
OEM/ODM
Model Rated Capacity Input Voltage Output Voltage Width Height Depth
HIS-50005KVA90-310V220V ±2%260mm360mm100mm
HIS-80008KVA90-310V220V ±2%360mm495mm100mm
HIS-1000010KVA90-310V220V ±2%360mm495mm100mm

Construction & Configuration

A wall-mountable steel cabinet houses the inverter stage, control board, and AVR/Bypass switching behind a front-facing digital display and terminal panel.

HIS inverter voltage stabilizer internal construction diagram
01

Steel Cabinet Enclosure

Powder-coated steel housing sized to frame — compact 260mm-wide cabinet for the 5KVA model, larger 360mm cabinet for the 8-10KVA models.

02

Inverter & Control Stage

DC bus conversion and PWM inversion electronics sit behind the front panel, driving the reconstructed 220V output.

03

Digital LCD Display

Front-panel screen reads live output and input voltage with a status/alarm indicator light.

04

AVR / Bypass Switch Panel

Dedicated changeover switches on the side panel let maintenance staff bypass the unit without external switchgear.

05

Input/Output Terminal Block

Rear/side-mounted terminal compartment for incoming and outgoing power connections.

06

Wall or Floor Mounting

Slim 100mm depth across all three models supports wall-mounted installation as well as floor placement.

Standards & Test Documentation

Documentation and compliance details are confirmed per order — reach out with your target market for the applicable certification set.

Technical Standard

Inverter Voltage Regulator Design

Built around double-conversion inverter principles common to online UPS and precision voltage regulation equipment.

Certification

Configurable by Market

Compliance markings and test reports are arranged to match your destination market's requirements — confirm at order time.

Documentation

Datasheets & Wiring Diagrams

Full parameter sheets and installation wiring diagrams available on request for procurement and engineering review.

Project Inquiry

Need a Voltage Stabilizer for Unstable Grid Conditions?

Tell us your incoming voltage range, load capacity, and site conditions — we'll configure a HIS unit or another series to match.